The words fire safety is written in. Assessments, duties, doors, compartments and escape routes — what each term actually means, what it obliges someone to do, and what goes wrong with it in a real building.

Anatomy of a fire door assembly A labelled drawing of a fire door in its frame, showing the leaf, frame, intumescent strip and smoke seal, fire-rated hinges, self-closing device, vision panel, keep shut signage and the threshold gap. Frame, fixed to thestructure Intumescent stripand smoke seal Fire-rated hinges Threshold gap Self-closing device Fire-rated visionpanel Door leaf, rated asan assembly Keep shut signage
A fire door assembly. Pick any term below to see it highlighted on this drawing, or on one of the others.

Assessment & duties

Fire risk assessment

A fire risk assessment is a structured review of a building that identifies fire hazards, who is at risk, and what must change to reduce that risk.

Responsible person

The responsible person is the individual or organisation carrying the legal duty for fire safety in a building — typically the employer, owner or occupier who controls the premises..

Competent person

A competent person is someone with the training, experience and knowledge to carry out a fire safety task properly.

Remedial action

A remedial action is a specific piece of work required to close a fire safety defect — raised from an assessment, an inspection or a check, assigned to someone, and evidenced when complete..

Fire safety training

Fire safety training is the instruction given to people at work so they know the fire risks where they are, what the alarm sounds like, how to raise it, and what to do when it goes off..

Fire risk assessment action plan

The action plan is the part of a fire risk assessment that lists what must be done, by whom and by when.

Fire risk assessment review

A review is a reconsideration of an existing fire risk assessment to check it is still valid.

Fire safety log book

A fire safety log book is the record of everything done to keep a building fire safe — alarm tests, equipment checks, drills, training, defects and their closure.

Hot works permit

A hot works permit is a written authorisation for work producing heat, sparks or flame — welding, grinding, soldering, torch-on roofing — issued for set conditions and signed back after a watch period..

Arson risk

Arson risk is the risk of a fire being started deliberately.

Passive fire protection

Fire door

A fire door is a door assembly designed to hold back fire and smoke for a rated period, keeping escape routes usable.

Compartmentation

Compartmentation is the division of a building into fire-resisting sections so that a fire is contained where it starts, protecting escape routes and limiting spread for a period..

Fire stopping

Fire stopping is the sealing of gaps and service penetrations through fire-resisting walls and floors, using tested systems, so the barrier performs for its rated period..

Fire resistance rating

A fire resistance rating is the period, in minutes, for which an element of a building has been tested to hold back fire.

FD30

FD30 describes a fire door assembly rated to resist fire for thirty minutes; FD60 is the equivalent at sixty.

Intumescent strip

An intumescent strip is a seal fitted into the edge of a fire door or its frame that expands when heated, closing the gap around the door and holding back fire and smoke..

Self-closing device

A self-closing device is the closer fitted to a fire door that returns it fully into its frame after use.

Fire door frame

A fire door frame is the lining the door leaf hangs in, fixed to the surrounding structure.

Fire door hinge

A fire door hinge is a hinge rated for use on a fire door assembly.

Threshold gap

The threshold gap is the clearance between the bottom of a fire door leaf and the floor.

Vision panel

A vision panel is a glazed opening in a fire door.

Fire door signage

Fire door signage is the marking on a fire door telling people how it must be left — most commonly Fire door keep shut, or Fire door keep locked where the door protects a store or riser..

Cold smoke seal

A cold smoke seal is a brush or fin seal around a fire door that resists the passage of smoke before there is enough heat to activate an intumescent strip.

Compartment wall

A compartment wall is a fire-resisting wall that divides a building into separate compartments.

Service penetration

A service penetration is any point where a pipe, cable, duct or tray passes through a fire-resisting wall or floor.

Compartmentation breach

A compartmentation breach is a hole or unsealed penetration through a fire-resisting wall or floor that lets fire and smoke pass.

Ceiling void

A ceiling void is the concealed space between a suspended ceiling and the structural floor above.

Cavity barrier

A cavity barrier is a construction fitted inside a concealed space to stop fire and smoke spreading through it.

Fire damper

A fire damper is a device fitted where a duct passes through a fire-resisting wall or floor.

Means of escape

Means of escape

Means of escape is the route and arrangements by which people can leave a building safely in a fire, from wherever they may be to a place of safety outside it..

Escape route

An escape route is the protected path people follow to leave a building in a fire — from the room they are in, through corridors and stairways, to a final exit..

Final exit

A final exit is the door at the end of an escape route where people leave the building into a place of safety in the open air, clear of the building and of any risk from it..

Emergency lighting

Emergency lighting is lighting that operates automatically when the normal supply fails, illuminating escape routes and exits for long enough to let people leave the building safely..

Personal emergency evacuation plan

A personal emergency evacuation plan, or PEEP, is an individual plan setting out how a named person who cannot evacuate unaided will leave the building in a fire, and who is responsible for helping them..

Travel distance

Travel distance is how far someone has to walk from anywhere in a building to reach a protected escape route or a final exit.

Protected route

A protected route is a part of an escape route enclosed in fire-resisting construction, so that people inside it are shielded from a fire elsewhere in the building while they leave..

Protected stairway

A protected stairway is a stair enclosed in fire-resisting construction, forming a protected route from the floors it serves down to a final exit.

Place of safety

A place of safety is where people are safe from the effects of the fire and free to disperse — normally open air, clear of the building and of anything falling from it..

Fire exit sign

A fire exit sign marks an escape route and the direction to follow along it.

Standards & legislation

Regulatory Reform (Fire Safety) Order 2005

The Regulatory Reform (Fire Safety) Order 2005 is the principal fire safety legislation for non-domestic premises in England and Wales.

Premises information box

A premises information box is a secure box at a building holding information the fire and rescue service needs on arrival — building plans, the evacuation strategy, and details of people who may need assistance..

Fire Safety Act 2021

The Fire Safety Act 2021 clarified that the Regulatory Reform (Fire Safety) Order 2005 applies to the structure, external walls and flat entrance doors of buildings containing two or more domestic premises..

Fire Safety (England) Regulations 2022

The Fire Safety (England) Regulations 2022 place specific duties on responsible persons for multi-occupied residential buildings in England, including information for residents and, for taller buildings, information for the fire and rescue service..

Building Safety Act 2022

The Building Safety Act 2022 created a regulatory regime for higher-risk buildings in England, introducing new duty holders, a safety case regime and the Building Safety Regulator..

Higher-risk building

A higher-risk building is a building that meets the criteria in the Building Safety Act regime, bringing it within the Building Safety Regulator's remit and the additional duties that come with it..

Golden thread

The golden thread is the requirement to create, keep and hand on accurate information about a higher-risk building's design, construction and management, in a form that stays usable over the building's life..